Note
Measurement Unit type is specific to Analysis type.
12.3.1 Time Waveform units conversion
Time Waveform units conversionTable 12-3:
Input Type Input Unit HW Int. Disp. Unit
AC V / E.U. no E.U.
ACCEL V / 32.2 ft/s
V / 32.2 ft/s
V / 9.81 m/s
V / 9.81 m/s
no
yes
no
yes
g
in./s
g
mm/s
VEL V / i/s
V / i/s
V / mm/s
V / mm/s
no
yes
no
yes
i/s
mil
mm/s
micron
DISP V / mil
V / micron
no
no
mil
micron
12.4 Non-Vibration unit analysis types
Non-Vibration unit analysis includes:
• Peak to Average Ratio
• Average to Minimum Ratio
• Kurtosis
• Skewness
• Synchronous Phase
These analysis types produce non-unit ratios or specific unit types such as degrees of
phase. Measurement Unit Type will not apply to these parameters.
12.5 Set DC offset
For thrust probes, the input channel is defined as a DC Process input. Set the DC offset so
that the thrust reading may be zeroed.
Procedure
1. Use a DC voltmeter (or the DHM program) to measure the DC voltage as seen
directly on the inputs.