Procedure
1. Cycle the power on each AMS Machinery Health Monitor that needs to get the new
firmware update from the FTP server.
2. Wait approximately 5 minutes for the system to complete the boot process.
3. Verify the system is powered on and in good status.
Refer to the Installation Manual for your specific hardware model for more
information.
Check the firmware version in AMS Machinery Manager
1. Log on to AMS Machinery Manager Client with the Administrator user account or a
user that has permission to use online technology.
2. Go to Tools > Setup/Communications > Online Configuration.
The Online Config window appears.
3. Go to File > Online Server > Open.
The Select Online Server Host Computer dialog appears.
4. Choose a server name from the menu and click OK.
The Online Server opens and a tree structure appears in the left pane of the Online
Config window.
5. In the tree structure, expand Units folder, and right-click the icon next to the AMS
Machinery Health Monitor you want to check and select Properties.
The Unit Properties screen appears in the right pane and displays the State,
Firmware Revision, DSP Revision, Total RAM, and Unit Type.
Unit propertiesFigure 8-2:
6. In the Unit Properties pane, verify State is Node(Unit)UP and Firmware Revision
matches the version you installed.
Software configuration
72 MHM-97125-PBF-EN, R0