Hazardous location installation
[32]
Table 6-1: cCSAus
(continued)
T6 -35°C ≤ Ta ≤ 50°C
T4 -35°C ≤ Ta ≤ 80°C
T2 -35°C ≤ Ta ≤ 80°C
Standards CSA E60079-15 (Zone 2, Type n)
UL 60079-15-02 2002 (Protection n)
CSA approval number CSA 18.70093801
Table 6-2: ATEX/IECEx
Intrinsically safe (Ex ia)
Identification
II 1G - Ex ia IIC T6, T4, T2 Ga
T6 -35°C ≤ Ta ≤ 50°C
T4 -35°C ≤ Ta ≤ 80°C
T2 -35°C ≤ Ta ≤ 80°C
Standards According to EU standard 94/9/EG
EN 60079-0:2012 +A11:2013, Equipment - general requirements
EN 60079-11:2012, Intrinsically safe "i"
IEC 60079-0:2011, Edition 6
IEC 60079-11:2011, Edition 6
ATEX approval number BVS 18 ATEX E 011 X
IECEx approval number IECEx BVS 18.0009X
Non-incentive (Ex nA)
Identification
II 3G -Ex nA [ic] IIC T6, T4, T2 Gc
T6 -35°C ≤ Ta ≤ 50°C
T4 -35°C ≤ Ta ≤ 80°C
T2 -35°C ≤ Ta ≤ 80°C
Standards According to EU standard 94/9/EG
EN 60079-0:2012 +A11:2013, Equipment - general requirements
EN 60079-15:2010, Non-sparking n
IEC 60079-0:2011, Edition 6
IEC 60079-15:2010, Edition 4
ATEX approval number BVS 18 ATEX E 011 X
IECEx approval number IECEx BVS 18.0009X