EasyManua.ls Logo

Emerson Daniel 3414 - K-Factor and Inverse K-Factor

Emerson Daniel 3414
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Conversion factors per units of measurement (continued)Table A-1:
Conversion factors Unit of measurement
6.289811 bbl/m
3
10
-3
Pa•s/cPoise
1.488 Pa•s/(lb/(ft•s))
A.2 K-Factor and inverse K-Factor
Frequency volumetric flow rate K-Factor Equation A-1:
 =


 3600
*
and
Frequency volumetric flow rate inverse K-Factor Equation A-2:
 =
 3600


*
where
KFactor
frequency “K-Factor” (pulses/volume**) (Freq1KFactor and Freq2KFactor)
InvKFactor
frequency “Inverse K-Factor” (volume**/pulse) (Freq1InvKFactor and
Freq2InvKFactor)
FreqQ
FullScale
frequency full-scale volumetric flow rate (volume**/time unit*)
(Freq1FullScaleVolFlowRate and Freq2FullScaleVolFlowRate)
MaxFreq
maximum frequency (Hz = pulses/time unit*) (Freq1MaxFrequency and
Freq2MaxFrequency)
* TimeUnit
time conversion factor depends on the VolFlowRate Time Unit data point:
volume/second = 1 s/s
volume/minute = 60 s/m
volume/hour = 3600 s/h
volume/day = 86400 s/d
** Volume
where the volume is selected via data points:
Units System
VolUnitUS
- gallons
Conversion factors
88 Gas Ultrasonic Flow Meters

Table of Contents

Other manuals for Emerson Daniel 3414

Related product manuals