EasyManua.ls Logo

Emerson Daniel Senior Orifice Fitting Series - Figure 5-1 Standard Grease - Type 1

Emerson Daniel Senior Orifice Fitting Series
138 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Owner and operator manual Section 5: Supplemental information
3-9008-001 Rev M January 2015
Lubricant information 99
Figure 5-1 Standard grease - Type 1
Pressure (psig) v. Temperature (°F) STANDARD GREASE - TYPE 1 - Part Number:1-213-04-001
OPTIMUM SEALING RANGE WITH NITROGEN FOR A 3" ANSI 600 SENIOR FITTING UNDER
LABORATORY CONDITIONS. Colored coordinate boxes indicate no detectable leakage at that
Temperature and Pressure for 30 minutes.
This information can be used as a guideline when evaluating measurement applications.
However, the pressure and temperature conditions to which a Senior may be exposed in an
application may differ significantly from laboratory conditions.
Important
Customers should not rely solely on this information but rather must perform adequate testing
on the particular application to confirm that the grease selected is appropriate for that
application and will operate as intended.

Table of Contents

Related product manuals