Owner and operator manual Section 2: Installation
3-9008-001 Rev M January 2015
General information 29
21TOP (14)
Section 2: Installation
Figure 2-1 Daniel Senior Orifice Fitting component identification
2.1 General information
The Daniel Senior Orifice Fitting is an essential element in an orifice plate flow measurement
system. Other elements in the system usually include, but are not limited to, a meter tube, a
flow conditioner, and various data recording devices. Purchasers have the option of acquiring
only a Daniel Senior Orifice Fitting unit from Daniel for later installation in a flow measurement
system, purchasing a Senior Orifice Fitting with a meter tube, or purchasing a complete orifice
plate flow measurement system containing a Senior Orifice Fitting.
Daniel hydrostatically tests every Senior unit for fluid retention, under factory controlled
conditions, to a minimum pressure of 1.5 times its rated maximum allowable operating
pressure.
Important
When purchasing a Daniel Senior Orifice Fitting for installation within a meter tube at a later
date, the hydrostatic testing of the Senior/meter tube assembly is the responsibility of the
product owners and product operating personnel only.