68 “Quick change” procedure
Section 4: Orifice plate installation and removal instructions Owner and operator manual
January 2015 3-9008-001 Rev M
34. Open the Bleeder Valve (10B) to vent the Top (14).
Step 34
Steps 35 and 36 are ONLY required for Seniors equipped with grease assisted, metal-to-metal
slide valves. Personnel operating the Daniel Senior Orifice Fittings equipped with O-Ring seal
“soft seat” design slide valves skip to step 37.
35. Remove the stem from the Grease Gun (23) with the Operating Wrench (2) and insert a
Daniel lubricant stick into the Grease Gun (23).

Table of Contents

Related product manuals