100-412-183 REV. 13 59
5.3.10 Available Analog Input Functions
* If the input signals are not within their valid range, or if left unconnected, the power supply will use 50%
amplitude and zero frequency offset, respectively.
Table 5.8 Available Analog Input Functions
Function Description Valid Range
Amplitude In
Controls the amplitude of ultrasonic
energy that will be delivered by the power
supply.
1 V to 10 V*
(10% to 100%)
Frequency Offset
Controls the frequency offset to the
power supply operating frequency. Actual
offset depends on the power supply
operating frequency:
1 V to 9 V*
(5 V is zero offset)
Frequency Offset Range
20 kHz +/- 400 Hz
30 kHz +/- 600 Hz
40 kHz +/- 800 Hz