DL8000 Preset Instruction Manual
Revised February-2016 Communications Protocols D-19
Authorize Transaction
[0x06]
Exceptions
Passcode Entry in Progress
Primary Alarm active
Transaction Authorized
Operating Mode is Manual
K&D Locked Out
Invalid recipe number (Recipe selected
[63,0,10] is more than number of recipes
[63,0,26])
No recipe selected (recipe selected [63,0,1] is
0)
Invalid additive selection method [63,0,102]
Invalid additive selection
Invalid swing arm side (applicable only for
Version 2.0 and later)
Recipe verification fail (error code [63,0,95] is
set)
Additive user program is not running in
DL8000
Additives module is running in DL8000 and
suggested additive method [63,0,170] is not
either 0 or 1. Returns Invalid additive selection
method exception.
Suggested additive method [63,0,170] is 0 and
additive bitmap [63,0,112] is set to more than
configured number of additives [63,0,100].
Suggested additive method [63,0,170] is 1 and
additive bitmap picked up (as per the additive
selection method) has additive bits set more
than configured number of additives
[63,0,100].
Supporting
Parameters
Additive selection method [63,0,102]
New recipe selection [63,0,10] [63,0,118]
Suggested additive method [63,0,170]
Forced additive selection bitmap [63,0,60]
[63,0,112]
No. of additives [63,0,100]
Number of data items [63,0,186]
Data items [63,0,188;190;192;194;196]
Results
When transaction gets authorized, the system
assigns it a transaction sequence number
[63,0,124]. In auto operating mode, the
configuration parameters are locked when
transaction is authorized.