DL8000 Preset Instruction Manual
D-20 Communications Protocols Revised February-2016
End Transaction
[0x07]
Ends a transaction if a transaction is authorized. If a transaction is in progress
and the DL8000 archive module is running, then the system archives the
transaction and displays “Archiving Transaction” and “Please Wait” messages
before ending the transaction. If the transaction is not in progress (that is, not
a single batch is delivered in this transaction), then the transaction aborts.
DL8000 displays a “Please wait” message until it receives the next command.
If an operator presses Stop while a transaction is in progress and the batch is
not in progress or the batch is stopped, then the DL8000 sets the Transaction
End Requested flag (bit 19 in [63,0,119]) to indicate the request for a
transaction end. The TAS then can issue an End Transaction command.
Flags Immediately Set
Transaction Ended
Flags Immediately
Cleared
Transaction in Progress
Transaction Authorized
Transaction End Requested
Exceptions
Batch in Progress
Operating Mode is Manual
No transaction authorized
Supporting
Parameters
None
Results
The transaction ends; if the transaction aborts
without delivering a single batch, the system
reduces the transaction sequence number
[63,0,124] by one.
Prompt Preset
Volume
[0x08]
Allows the TAS to let an operator enter a preset volume at the keypad.
Issuing this command locks the keypad and display to the TAS. The DL8000
displays a preset selection screen. If the suggested preset volume [63,0,185]
is greater than zero, the DL8000 “pre-types” the suggested preset volume.
The operator can press Enter to accept displayed preset volume or press Alt
+ Backspace to enter another preset volume.
The operator must enter the preset within the timeout time [63,0,171];
otherwise the operation aborts and sets the Operation Timed Out flag (bit 3 in
[63,0,119]).
If you set the timeout to zero, then the timeout doesn’t occur. You must then
use the Timeout Operation command (0x05) to end this operation.
Flags Immediately Set
K&D Locked Out
Flags Immediately
Cleared
Operation Timed Out
Preset Volume Entered
Exceptions
Passcode Entry in Progress
Batch in Progress
Primary Alarm active
Operating Mode is Manual
No transaction authorized
K&D Locked Out
Supporting
Parameters
Suggested preset volume [63,0,185]
Preset volume entered [63,0,39]