DL8000 Preset Instruction Manual
Revised February-2016 Communications Protocols D-39
Authorize
Batch
[0x0A]
Flags Immediately
Cleared
Preset Volume Entered
Operation Timed Out
Batch Ended
Batch Aborted
Batch Stopped
Batch in Progress
Exceptions
Passcode Entry in Progress
Primary Alarm
Batch Authorized
No transaction authorized
Operating Mode is Manual
K&D Locked Out
Invalid Preset volume
Flow Rate Too High/Low
Invalid Number of Components
Maximum Batches Delivered for Transaction
(0x57)
Maximum Transaction Total (0x5F)
Tolerance error (0x5B)
Supporting
Parameters
Preset volume entered [63,0,39]
Timeout time [63,0,171]
Results
When the batch authorizes, the DL8000 displays a
loading screen. The DL8000 presets the batch and
displays "Start to Load” and “Stop to Abort"
messages. The operator has to initiate loading by
pressing Start within the timeout time [63,0,171]. If
the batch aborts (that is, the operator presses
Stop instead of Start or the DL8000 times out
waiting for the Start key to be pressed), the
DL8000 sets the Batch Aborted and Operation
Timed Out flags (bits 14 and 3) and resets the
Batch Authorized flag (bit 17 in [63,0,119]). This
also reduces by 1 the batch sequence number
[63,0,125].
Deviations
Does not support exceptions “Program Code
Value is Weights & Measures” and “Program
Code is Read-only.”
Does not use the backup density, backup
gravity, or backup temperature for all batch
components sent in the DanLoad 6000
command frame. If the TAS tries to set the
backup density using this command, the
DL8000 updates the base density of the
corresponding product.
Exception codes [0x57], [0x5B], and [0x5F]
are not available in the original DanLoad 6000
protocol.
Supports additional exception Flow Rate Too
High/Low