DL8000 Preset Instruction Manual
D-62 Communications Protocols Revised February-2016
Swing Arm Side
[0x33]
Deviations
Swing arm features is not implemented in
DL8000. Some TAS use current side, so
DL8000 gives the value stored in [63,0,145]
(applicable only for Version 1.0).
None (applicable only for Version 2.0 and
later).
Weights & Measures
Switch
Reports the current state (0=Open or 1=Closed) of the Weights & Measures
switch from location [62,0,148]. You cannot modify any defined Weights &
Measures parameters when the Weights & Measures switch is closed.
None
Flags Immediately
Cleared
None
Exceptions
None
Supporting
None
As above
None
Change
Operating Mode
[0x37]
Allows the TAS to change the DL8000’s operating mode with options (0=Auto,
1=Manual) as received in the command request frame. If the DL8000 is
already in the desired mode then the command is simply acknowledged.
For Version 1.0: Mode does not change if batch halts at alarm halt.
For Version 2.0: In auto mode, if alarm raises then mode changes to manual
and current batch completed before ending the transaction.
If transaction is authorized and this command is issued then the DL8000 ends
the current transaction. The operating mode changes after the current
transaction ends.
Flags Immediately Set
Operating Mode is Manual (when new mode is
manual)
Flags Immediately
Cleared
Operating Mode is Manual (when new mode is
auto)
Operation Timed Out
Recipe Selected
Additive Selected
Preset Volume Entered
Keypad Data Available
K&D Locked Out
Exceptions
No batch stopped
Batch is in progress and any non primary
alarm with severity more than info (1) is active.
Batch is in progress and any primary alarm is
active.
Invalid operating mode
Supporting
None