DL8000 Preset Instruction Manual
Revised February-2016 Communications Protocols D-67
Byte 3 Bit 3: Comp Pressure [61,0,152]
Byte 3 Bit 4: Comp Base Density [61,0,153]
Byte 3 Bit 5: Batch Start Indicated [61,0,195]
Byte 3 Bit 6: Batch End Indicated [61,0,196]
Byte 3 Bit 7: Average component k-factor
[61,0,205]
Byte 4 Bit 0: Average component meter factor
(FWA) [61,0,206]
Byte 4 Bit 1: Average component CTL (FWA)
[61,0,215]
Byte 4 Bit 2: Average component CPL (FWA)
[61,0,216]
Byte 4 Bit 3: Comp Observed density [61,0,225]
Byte 4 Bit 4: Density Units (archived by default)
[61,0,249]
If the bit for archive configuration parameter is 1,
then the value of that parameter from the batch
record is included in the response frame. Each
history data is returned as consecutive 4-bytes
data. All the parameters of double data type in
DL8000 are returned as 4-bytes unsigned long
and all others will be returned as 4-bytes float
data.
Some of the batch data is archived by default and
not configurable. Refer to Section C.2.5,
Transaction History in Appendix C in the
ROCLINK 800 Configuration Software User
Manual (for DL8000), (Form A6240) for details.
The parameter values are returned in the same
order in which the configuration bits are reported.
All the copies archived for each configured archive
parameter are returned in the response frame.
The number of copies archived for each parameter
is always fixed. For example, 4 for data referring to
components, 4 for data referring to meters, and 6
for data referring to additives.
Example: If configstatus[6](hex) = 7D 01 00 10 00
00, then data following the configstatus[6] in the
response frame has the format:
float Base Temp Option
float FWA Base Density
float FWA Temp
float Batch Preset Qty
unsigned long Batch Gross Qty
unsigned long Batch Std Qty
unsigned long Gross Qty Comp 1
unsigned long Gross Qty Comp 2
unsigned long Gross Qty Comp 3
unsigned long Gross Qty Comp 4
float Density Units
Note: The DL8000 does not consider the
multiplication factors used for returning
some parameters in other DanLoad 6000
commands when returning the value (read
from the archived data) in the response