DL8000 Preset Instruction Manual
Revised February-2016 DL8000 Keypad Display E-71
If you enter a prover volume of zero, the system retains the old meter
factor.
Single MF/K-factor
Option
When you press ENTER, the system updates the meter factor parameter
[69,X,9] with the new value and displays a screen allowing you to rerun
the batch.
If you press STOP, the system retains the current meter factor
parameter value and displays a screen allowing you to rerun the batch.
If you press EXIT, the system redisplays the prover volume entry
screen, which you can use to re-enter the prover volume.
Multiple MF/K-factor
Option
When you press ENTER, the system updates the meter factor using the
new value.
Depending upon the selected flow rate set point, the system updates the
meter factor to the appropriate TLP (that is, if 1 is the selected flow rate
set point, the system updates the parameter Meter Factor 1 [69,x,75].
Similarly, if the MAX FR SP is 4, the system updates the parameter
Meter Factor 4 [69,X,81] and then displays a screen allowing you to
rerun the batch.
If you press STOP, the system retains the current meter factor value
(Meter Factor, [69,X,81]), and then displays a screen allowing you to
rerun the batch.
If you press EXIT, the system redisplays the prover volume entry
screen which you can use to re-enter the prover volume.
Flow Alarm or Fallback
Alarm During Proving
Batch Loading
If a flow alarm or fallback alarm occurs during batch delivery, the
system does not prompt you to enter a prover volume. Instead, the
system displays a warning screen showing the particular error:
14/03/12 12:26:02
WARNING!!!
Flow Alarm
during Batch
ENTER To Continue
EXIT To rerun
Note: Flow alarms include Low Flow, High Flow, No Flow,
Unauthorized Flow, and Unable to Close Valve.
14/03/12 12:26:02
WARNING!!!
Fallback
during Batch
ENTER To Continue
EXIT To rerun