DL8000 Preset Instruction Manual
E-100 DL8000 Keypad Display Revised February-2016
Set Port
Rx Bytes / Tx Bytes
Baud rates
Par/StopBit/DataBit
Diag. in progress…
RS485 ch 4
120/120
PPPPPPPPP
The system also tests parity bits, stop bits, and data bits, again using P
to indicate a successful test and F to indicate a failure. When the test
completes the message STOP to End appears at the bottom of the
screen:
Set Port
Rx Bytes / Tx Bytes
Baud rates
Par/StopBit/DataBit
RS485 ch 4
120/120
PPPPPPPPP
PPP
Press STOP to end the test and return to the comm port selection
screen. Press EXIT to display the Diagnostics main menu.
E.5.8 Error Messages
Table E-11 lists error messages that could appear on the DL8000
display.
Table E-11. Error Messages
Archive Config Err Transaction or batch configuration error
Blend Toler. Fail Preset verification failed; component percentages
are out of allowed tolerance limit
Btch/Trans Lmt Cros Preset verification failed; limit on batches per
transaction exceeded.
Invd Additive Additive verification failed
Inv Adtv type Recipe verification failed; invalid additive type
Invd Comp Ratio Recipe verification failed; invalid component ratio
in selected recipe
Invd Delivery Seq Recipe verification failed; invalid delivery
sequence
Invd Meter Recipe verification failed; invalid meter
assignment
Invd Driver Invalid driver ID entered
Invd Prset Adtv op Recipe verification failed; invalid additive preset
option