8.9 Menu J: Monitoring
Parameter
Range(Ú) Default(Ö)
Type
Open-Loop RFC-A RFC-S Open-Loop RFC-A RFC-S
J01 Drive Type 0 to 255 RO Num ND NC PT
J03 Elevator Software State 0 to 14 0 to 3
RO Num ND NC PT
J04 Firmware Version 0 to 99999999
RO Num ND NC PT
J05 Maximum Heavy Duty Rating 0.000 to 99999.999 A
RO Num ND NC PT
J06 Drive Full Scale Current Kc 0.000 to 99999.999 A
RO Num ND NC PT
J07 Drive Rated Voltage 200V (0), 400V (1), 575V (2), 690V (3)
RO Txt ND NC PT
J08 Drive Contol Mode Active
Open-loop (1), RFC-A (2), RFC-S (3),
Regen (4)
RO Txt ND NC PT US
J09 Reference Parameter Selected 0 to 10
RO Num ND NC PT
J10 V1 Calculated Deceleration Distance 0 to 10000
RO Num ND NC PT
J11 V2 Calculated Deceleration Distance 0 to 10000
RO Num ND NC PT
J12 V3 Calculated Deceleration Distance 0 to 10000
RO Num ND NC PT
J13 V4 Calculated Deceleration Distance 0 to 10000
RO Num ND NC PT
J14 V5 Calculated Deceleration Distance 0 to 10000
RO Num ND NC PT
J15 V6 Calculated Deceleration Distance 0 to 10000
RO Num ND NC PT
J16 V7 Calculated Deceleration Distance 0 to 10000
RO Num ND NC PT
J17 V8 Calculated Deceleration Distance 0 to 10000
RO Num ND NC PT
J18 V9 Calculated Deceleration Distance 0 to 10000
RO Num ND NC PT
J19 V10 Calculated Deceleration Distance 0 to 10000
RO Num ND NC PT
J20 Final Current Reference ±VM_TORQUE_CURRENT %
RO Num ND NC PT FI
J21 Final Current Limit ±VM_TORQUE_CURRENT %
RO Num ND NC PT
J22 Total Output Current ±VM_DRIVE_CURRENT_UNIPOLAR A
RO Num ND NC PT FI
J23 Percentage Load ±VM_USER_CURRENT %
RO Num ND NC PT FI
J24 Torque Producing Current ±VM_DRIVE_CURRENT A
RO Num ND NC PT FI
J25 Magnetizing Current ±VM_DRIVE_CURRENT A
RO Num ND NC PT FI
J26 Motor Protection Accumulator 0.0 to 100.0 %
RO Num ND NC PT PS
J27 Final Torque Reference ±VM_TORQUE_CURRENT %
RO Num ND NC PT FI
J28 Final Current Filter Time Constant
0.0 to 25.0 ms 0.0 ms RW Num US
J29
Open-Loop: Current Controller Kp
Gain
0 to 30000
20 RW Num US
RFC-A: Final Current Loop Kp
0 to 30000 150 RW Num US
RFC-S: Final Current Loop Kp
0 to
30000
150 RW Num US
J30 Final Current Loop Ki 0 to 30000 40 2000 RW Num US
J31 Speed Error
±VM_SPEED RO Num ND NC PT FI
J32 Speed Loop Output
±VM_TORQUE_CUR
RENT %
RO Num ND NC PT FI
J33 Final Speed Loop Kp
0.0000 to
200.0000 s/rad
0.0300 s/rad RW Num US
J34 Final Speed Loop Ki
0.00 to 655.35 s²/rad 0.10 s²/rad RW Num US
J35 Field Weakening Magnetizing Current 0 to 100 %
RO Num ND NC PT
J36 Elevator Position
-2147483648 to
2147483647 mm
RO Num ND NC PT
J37 Calculated Nominal Motor Speed rpm 0 to 32767 rpm
RO Num ND NC PT
J38 Active Speed Setpoint 0 to 10000 mm/s
RO Num ND NC PT
J39 Profile Speed 0 to 10000 mm/s
RO Num ND NC PT
J40 Actual Speed
0 to 10000 mm/s RO Num ND NC PT
J41 Reference Acceleration 0 to 10000 mm/s²
RO Num ND NC PT
J42 Deceleration Distance 0 to 32767 mm
RO Num ND NC PT
J43 Deceleration Distance Calculated 0 to 10000 mm
RO Num ND NC PT
J44 Deceleration Distance Measured 0 to 32767 mm
RO Num ND NC PT
J45 Creep Distance Measured 0 to 32767 mm
RO Num ND NC PT
J46
Speed At Floor Sensor Correction
Active
0 to 32767 mm/s RO Num ND NC PT
J47
Remaining Floor Sensor Correction
Distance
-32768 to 32767 mm RO Num ND NC PT
J48 Velocity Threshold 1 Status Output Off (0) or On (1)
RO Bit ND NC PT
J49 Velocity Threshold 2 Status Output Off (0) or On (1)
RO Bit ND NC PT
J50 Final Speed Reference
±VM_SPEED RO Num ND NC PT FI
J51 Speed Feedback
±VM_SPEED RO Num ND NC PT FI
J52 Drive Encoder Revolutions
0 to 65535 RO Num ND NC PT PS