E300 Design Guide 351
Issue Number: 1
This indicates the elevator position in mm units.
There are two possible display modes:
· Position Display Mode (H30) = Relative (0), the position relative to the travel start position is shown.
· Position Display Mode (H30) = Absolute (1), the absolute shaft position is shown.
See Position Display Mode (H30) for more information.
This indicates the elevator calculated motor speed in rpm units, before roping or gearbox ratios have been applied. This value is calculated when
Nominal Elevator Speed (E01) to Gear Ratio Denominator (E05) are modified.
In Open loop mode the relationship between rpm and frequency is Nominal elevator frequency = Nominal elevator speed rpm * motor rated frequency
/ Motor synchronous speed.
This indicates the active elevator speed set point in mm / s. i.e. the presently selected profile speed from V1 Speed Reference (G01) to Speed
Reference (G10) If no speed has been selected this will show 0 mm / s.
This indicates the profile generator output speed in mm / s units. The profile generator output speed is based upon the profile specified by the Profile
category parameters.
This indicates the actual speed of the motor in mm / s units.
In RFC-A and RFC-S:
The actual speed is based upon the encoder feedback and motor rated speed mm/s and rpm scaling.
J36 Elevator Position
Mode RFC-A, RFC-S
Minimum -2147483648 Maximum 2147483647
Default Units mm
Type 32 Bit Volatile Update Rate Background
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
J37 Calculated Nominal Motor Speed rpm
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 32767
Default Units rpm
Type 16 Bit Volatile Update Rate Background
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
J38 Active Speed Setpoint
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 10000
Default Units mm / s
Type 16 Bit Volatile Update Rate Background
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
J39 Profile Speed
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 10000
Default Units mm / s
Type 16 Bit Volatile Update Rate Background
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
J40 Actual Speed
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 10000
Default Units mm / s
Type 16 Bit Volatile Update Rate Background
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT