User Menu A Commissioning
Advanced
Parameters
Diagnostics Optimization CT MODBUS RTU Technical Data
428 E300 Design Guide
Issue Number: 1
Mode: Open-Loop, RFC-A, RFC-S
Up to four scope sources can be selected using Data Logger Trace 1 Source (Y02) to Data Logger Trace 4 Source (Y05). If the source value is set to
0.000, or the source parameter does not exist or is non-visible, then no source is selected. The sources do not operate in the same way as normal
source parameters in that the input to the scope is the actual value of the parameter and not a value scaled to a percentage based on the range of the
parameter. If a scope trace source parameter is modified the actual change is not effective until the drive is reset.
See Data Logger Trace 1 Source (Y02).
Parameter
Range(Ú) Default(Ö)
Type
Open-Loop RFC-A RFC-S Open-Loop RFC-A RFC-S
Y02 Data Logger Trace 1 Source A00 to AB99 A00 RW Num PT US
Y03 Data Logger Trace 2 Source A00 to AB99 A00 RW Num PT US
Y04 Data Logger Trace 3 Source A00 to AB99 A00 RW Num PT US
Y05 Data Logger Trace 4 Source A00 to AB99 A00 RW Num PT US
Y06 Data Logger Trigger Off (0) or On (1) Off (0) RW Bit
Y07 Data Logger Trigger Source A00 to AB99 A00 RW Num PT US
Y08 Data Logger Trigger Threshold -2147483648 to 2147483647 0 RW Num US
Y09 Data Logger Trigger Invert Off (0) or On (1) Off (0) RW Bit US
Y10 Data Logging Mode Single (0), Normal (1), Auto (2) Single (0) RW Txt US
Y11 Data Logger Arm Off (0) or On (1) Off (0) RW Bit NC
Y12 Data Logger Data Not Ready Off (0) or On (1)
RO Bit ND NC PT
Y13 Data Logger Saving Data Off (0) or On (1)
RO Bit ND NC PT
Y14 Data Logger Sample Time 1 to 200 1 RW Num US
Y15 Data Logger Trigger Delay 0 to 100 % 0 % RW Num US
Y16 Data Logger Time Period 0.00 to 200000.00 ms
RO Num ND NC PT
Y17 Autosave Mode
Disabled (0), Overwrite (1),
Keep (2)
Disabled (0) RW Txt US
Y18 Data Logger Autosave File Number 0 to 99 0 RO Num PS
Y19 Data Logger Autosave Reset Off (0) or On (1) Off (0) RW Bit
Y20 Data Logger Autosave Status
Disabled (0), Active (1),
Stopped (2), Failed (3)
Disabled (0) RO Txt PS
RW Read / Write RO Read-only Bit Bit parameter Txt Text string Date Date parameter Time Time parameter
Chr
Character
parameter
Bin Binary parameter IP IP address Mac MAC address Ver Version number SMP
Slot, menu,
parameter
Num Number parameter DE Destination ND No default value RA Rating dependent NC Non-copyable PT Protected
FI Filtered US User save PS Power-down save
Y02 Data Logger Trace 1 Source
Mode Open-Loop, RFC-A, RFC-S
Minimum A00 Maximum AB99
Default A00 Units
Type 16 Bit User Save Update Rate Drive reset read
Display Format Menu Param Alpha Numeric Decimal Places 0
Coding RW, PT, BU
Y03 Data Logger Trace 2 Source
Mode Open-Loop, RFC-A, RFC-S
Minimum A00 Maximum AB99
Default A00 Units
Type 16 Bit User Save Update Rate Drive reset read
Display Format Menu Param Alpha Numeric Decimal Places 3
Coding RW, PT, BU