5-3 L5005EA
3. Auto Calibration
Purpose: To bring the color adjustment of each
component into standard alignment.
Symptom of Misadjustment: If this adjustment is
incorrect, component signals do not reproduce the
corresponding color.
1. Input 11step Gray Scale signal (0 IRE-100 IRE /
step by 10 IRE) into only Y terminal of Component 1.
2. Enter the service mode.
3. To enter the Auto Calibration adjustment mode,
press [6] button on the service remote control unit.
4. To start auto adjustment, press [CH o] button on
the service remote control unit.
- Upon completion, “Calibration Check OK” and
“Push FCH UP key” appear on the screen.
- If the auto adjustment failure, “Calibration Check
NG” and “Push FCH UP key” appear on the
screen.
5. Unplug AC cord and plug it in AC outlet again to
reset then enter the service mode again.
4. Flicker Adjustment
*This adjustment is required when reparing T-CON
CBA.
1. Enter the Service mode. (See page 5-1.)
2. Press [2] button on the remote control unit.
The following screen appears.
3. If Flicker Adjustment is not fit, the screen become
the following.
4. Turn the VR1 on the LCD Module so that flash
stops.
INPUT SIGNAL
(11step Gray Scale pattern)
FLASH (Go and Off)