WF8
TYPEA
TYPEB
WF8
WF9 WF9
WF8WF10
WF8WF11
WF8WF10
WF8WF11
WF8WF13
WF8WF14
WF8WF13
WF8WF14
WF8
WF8
WF8
WF8
1-9-26 1-9-27 1-9-28
BHB400F01017-A
Main CBA Bottom View
NOTE :
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
CAUTION !
Fixed voltage power supply circuit is used in this unit.
If Main Fuse (F001) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
CAUTION
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,
REPLACE ONLY WITH THE SAME TYPE FUSE.
ATTENTION : POUR UNE PROTECTION CONTINUE LES RISQES
D'INCELE N'UTILISER QUE DES FUSIBLE DE MEMO TYPE.
RISK OF FIRE-REPLACE FUSE AS MARKED.
"This symbol means fast operating fuse."
"Ce symbole reprèsente un fusible à fusion rapide."
A V
F
BECAUSE A HOT CHASSIS GROUND IS PRESENT IN THE POWER
SUPPLY CIRCUIT , AN ISOLATION TRANSFORMER MUST BE USED.
ALSO , IN ORDER TO HAVE THE ABILITY TO INCREASE THE INPUT
SLOWLY , WHEN TROUBLESHOOTING THIS TYPE POWER SUPPLY
CIRCUIT , A VARIABLE ISOLATION TRANSFORMER IS REQUIRED.
Note:
The Tuner Unit ( TU701 ) is either type A or type B.
Wave Form will be different. It depends on the type of
tuner used on the unit you are servicing.
NOTE :
Either BHB400F01016, BHB400F01017
is used for the Main CBA in this S/M.