FB1100/FB1200 Flow Computer Termination Board Field Replacement Guide
D301820X012
November 2020
3
Item
Field Replacement Kit
Part Number
6-connector pluggable terminal blocks (pack of 4) 395791014-KIT
8-connector pluggable terminal blocks (pack of 4) (Used with
any FB1200 Flow Computer which has a 6-channel expansion I/O
board)
395803000-KIT
Ambient Temperature Range
May be used up to a maximum ambient temperature of 80˚C and a minimum ambient
temperature of -40˚C; see product data plate (on device) for ambient temperature.
Required Tools
#1 Phillips-head screwdriver
#2 Phillips-head screwdriver
3/32-inch flat head screwdriver (for 3.81 mm pitch terminal block connections)
1/8-inch flat-head screwdriver (for 5.08 pitch terminal block connections)
3mm hexagonal torque wrench. Ranges must cover 10 to 12 in-lbs (1.1 to 1.4 N-m).
Electrical Ratings
I/O Ratings (FB1200 Flow Computer):
o
4 Digital Outputs: 0.5A, 24Vdc
o
2 Analog Outputs: 4-20 mA
Important
Only use accessories supplied with the flow computer or sold by Emerson as spare parts for this
flow computer. Substituting a part you obtain elsewhere (such as a battery)
voids your approval
certification.
WARNING
EXPLOSION HAZARD Substitution of any components may impair suitability for Class I,
Division 1 or Class I, Division 2.
WARNING
Do not disconnect equipment unless power has been removed or the area is known to be non-
hazardous.
WARNING
EXPLOSION HAZARD Do not replace batteries unless power has been switched off or the
area is known to be non-hazardous. Batteries must only be changed in an area known to be
non-hazardous.