8-14
PIN 17 OF
CN302
WF6
PIN 19 OF
CN302
WF2
PIN 14 OF
CN302
WF4
PIN 16 OF
CN302
WF5
PIN 21 OF
CN302
WF3
PIN 23 OF
CN302
WF1
PIN 3 OF
CN303
WF7
Power Supply CBA Bottom View
BA8AN0F01012-1
Because a hot chassis ground is present in the power
supply circuit, an isolation transformer must be used.
Also, in order to have the ability to increase the input
slowly,when troubleshooting this type power supply
circuit, a variable isolation transformer is required.
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F601) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
For continued protection against risk of fire,
replace only with same type 4 A, 125V fuse.
CAUTION ! :
ATTENTION : Utiliser un fusible de rechange de même type de 4A, 125V.
4A/125V