3. Begin the batch.
Option Description
Display Choose MenuBatcherRun BatchBatch Control and select Begin.
ProLink III Choose Device ToolsApplication ControlBatchingRun Batcher and
select Begin Batch.
Field communicator Not available
The transmitter automatically resets the batch total to 0 if you have selected Reset on Start. Otherwise,
you must manually reset the batch total before the batch will start.
4. Monitor the batch during processing.
Option
Description
Display Choose MenuBatcherRun Batch and observe the value displayed in Batch
Total.
ProLink III Choose Device ToolsApplication ControlBatchingRun Batcher and
observe the values displayed in Current Total and Batch Time.
Field communicator Not available
5. Optional: Pause the batch at any time.
Option
Description
Display Choose MenuBatcherRun BatchBatch Control and select Pause.
ProLink III Choose Device ToolsApplication ControlBatchingRun Batcher and
select Pause Batch.
Field communicator Not available
Pausing a batch allows you to resume it later.
6. Optional: Resume the batch after it has been paused.
Option
Description
Display Choose MenuBatcherRun BatchBatch Control and select Resume.
ProLink III Choose Device ToolsApplication ControlBatchingRun Batcher and
select Resume Batch.
Field communicator Not available
Operation using the batcher Configuration and Use Manual