EasyManua.ls Logo

Emerson Micro Motion 1700 - Introduction to configuration and commissioning

Emerson Micro Motion 1700
122 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.3 Rotate the user interface on the transmitter
(optional)
The user interface on the transmitter electronics module can be rotated 90º or 180° from
the original position.
Display componentsFigure 2-2:
A
B
C
G
E
F
D
A. Transmitter housing
B. Sub-bezel
C. Display module
D. Display screws
E. End-cap clamp
F. Cap screw
G. Display cover
Notes
When using the touch buttons, you must cover at least an 8 mm diameter circle over the
surface above the touch button: using your thumb may be more effective because it has a
greater surface area.
When the housing cover is removed, the touch buttons do not function.
Procedure
1. Shut off power to the unit.
2. Remove the end-cap clamp by removing the cap screw.
3. Turn the display cover counterclockwise to remove it from the main enclosure.
4. Carefully loosen (and remove if necessary) the semicaptive display screws while
holding the display module in place.
5. Carefully pull the display module out of the main enclosure until the sub-bezel pin
terminals are disengaged from the display module.
Mounting and sensor wiring for integral installations
Installation Manual 13

Table of Contents

Other manuals for Emerson Micro Motion 1700

Related product manuals