8.5.2 Hazardous area frequency/discrete output wiring using
galvanic isolator
Hazardous area frequency/discrete output wiring using galvanic
isolator
Figure 8-10:
Hazardous area
Safe area
A
B
C
D
E
7
9
+ G
1
5
A. External power supply
B. V
out
C. R
load
D. Galvanic isolator (see note)
E. Counter
Note
The galvanic isolator shown here has an internal 1000 Ω resistor used for sensing current:
ON > 2.1 mA
OFF < 1.2 mA
These current switching levels comply with DIN19234 (NAMUR)/DIN EN 60947-5-6/IEC 60947-5-6.