Figure 8-1: Effect of mA Output Direction on an mA Output: Lower Range Value = 0
mA Output Direction = Normal
mA output
-x 0 x
Reverse flow Forward flow
20
12
4
mA Output Direction = Absolute Value
mA output
-x 0 x
Reverse flow Forward flow
20
12
4
• Lower Range Value = 0
• Upper Range Value = x
Figure 8-2: Effect of mA Output Direction on an mA Output: Lower Range Value < 0
mA Output Direction = Normal
mA output
-x 0 x
Reverse flow Forward flow
20
12
4
mA Output Direction = Absolute Value
mA output
-x 0 x
Reverse flow Forward flow
20
12
4
• Lower Range Value = −x
• Upper Range Value = x
mA Output Direction = Normal and Lower Range Value = 0
Configuration:
Integrate the meter with the control system Configuration and Use Manual
March 2019 MMI-20025166
142 Micro Motion Model 5700 Transmitters with Configurable Outputs