4.6 Wire the Discrete Output
Use this section to wire the Discrete Output in explosion-proof, nonincendive, or
nonhazardous installations.
Important
Meter installation and wiring should be performed only by suitably-trained personnel.
4.6.1 Wire the Discrete Output (internally powered)
Use this procedure to wire the internally-powered Discrete Output for Channel B or C.
Procedure
Wire to the appropriate output terminal and pins.
Figure 4-16: Discrete Output wiring (internally powered)
A
D
C
B
A. Discrete Output
B. Channel B or C
C. See Figure 4-17 for output amplitude versus load resistance
D. Counter
Figure 4-17: Internally powered Discrete Output: output amplitude versus load
resistance [24 VDC (Nom) open circuit]
A. Output amplitude (V)
B. Load resistor (Ω)
Wiring the channels Installation Manual