EasyManua.ls Logo

Emerson Micro Motion Elite Coriolis CMF350 - Connect the wires to the core processor terminals

Emerson Micro Motion Elite Coriolis CMF350
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A. Drain wires wrapped around shield
7. For foil (shielded cable) only:
Note
For braided (armored cable) skip this step and contine to the next step.
Option Description
NPT gland
type
a. Slide the shielded heat shrink over the drain wires. Ensure that the wires are
completely covered.
b. Apply heat (250 °F or 120 °C) to shrink the tubing. Do not burn the cable.
c. Position the clamping insert so the interior end is flush with the braid of the
heat shrink.
A. Shielded heat shrink
B. After heat is applied
M20 gland
type
Trim 0.3 in (7 mm).
A. Trim
8. Assemble the gland by folding the shield or braid back over the clamping insert and
1/8 inch (3 mm) past the O-ring.
A. Shield folded back
9. Install the gland body into the conduit opening on the core processor housing.
10. Insert the wires through the gland body and tighten the gland nut onto the gland
body.
Transmitter power and I/O wiring
Installation Manual 25

Related product manuals