4 Programming
4.1 Main menu
The main menu provides access to various functional settings and viewing of current
settings. The following options/settings are available in the main menu.
Set Zero
Sensitivity Settings
Review Relay Settings
Set Relay Options
Select Display Language
4.2 Accessing the main menu
There are two ways to access the main menu, either by using the setup button on the
faceplate of the transmitter or utilizing the magnetic Reed switch.
Press and hold the Setup button to access the main menu.
Place and hold the magnet to the transmitter’s housing (10 o’clock position as shown in
Figure 3-1) to access the main menu.
4.3
Main menu functionality
Ensure that the transmitter has been turned on and that no fault is present. If a fault is
present, the menu system will not be accessible.
Refer to Figure 4-2 for the programming flow chart for the Millennium transmitter. The
following steps outline the actions required to navigate through the menu system:
Press and hold the Setup button or hold the magnet next to the triangle on the
faceplate as shown in Figure 3-1 until the message Switch On displays and the
countdown (10 to 0) finishes.
An option will scroll across the display followed by the prompt YES?.
To set/view an option, momentarily press the Setup button or place the magnet to
the Reed switch at the YES? prompt.
If you do not wish to select that option wait five (5) seconds until the next option
appears and then select YES?.
A selection is acknowledged with a flashing YES.
If no option is selected, the transmitter returns to the normal operational mode and
the display will read Clear.
Programming