15 PACSystems™ RX3i 64 MB CPU w/Ethernet Quick Start Guide GFK-2941K
Module Start-up
You Will Need:
An RX3i Universal Backplane: IC695CHS007, IC695CHS012 or
IC695CHS016.
This PACSystems RX3i CPU. This CPU occupies two backplane slots.
An RX3i rack-mounted Power Supply Module and compatible power
source
(AC
1
or DC).
A computer running PAC Machine Edition (PME) configuration and
programming software. PME Version 9.70 SIM 16 or later supports all
features in this document.
Ethernet cable for connecting the PME programmer computer to the
RX3i CPU.
Phillip’s head screwdriver.
A very small slotted screwdriver (1.4 mm jewelers size).
1
On lightly-loaded racks, use IC695PSA040H or later, or IC695PSA140D or later, otherwise power-
up may be unsuccessful. Alternately, fill out the empty slots in the rack to draw more current.