Rosemount Model 1195/ProPlate/Mass ProPlate
10-10
KEMA/CENELEC
('
Explosion Proof.
EEx d IIC T5 (Tamb = 70 C); EEx d IIC T6
(Tamb = 40 C).
Enclosure Type: IP65.
,'
Intrinsically Safe.
EEx ia IIC T5 (Tamb = -45 to +40°C); EEx ia IIC T54 (Tamb = -45 to
+70°C).
Enclosure Type: IP65.
Ui = 30V dc.
Ii = 200 mA.
Pi = 0.9 W.
Ci = 0.012 uF.
Li = 0.
MASS PROPLATE
FLOWMETER
Ordering Information
Ordering information is available in the ProPlate, Mass ProPlate, and
Model 1195 Integral Orifice Product Data Sheet, publication number
00813-0100-4686.
Functional Specifications Service
(1)
Liquid, gas and steam service.
Pipe Sizes
½ in. (15 mm), 1 in. (25 mm), and 1½ in (40 mm).
Absolute/Gage Sensor
Ranges
Range 3: 08 to 0800 psia (055.16 to 05515.8 kPaA).
Range 4: 036.26 to 03,626 psia (0250 to 025000kPaA).
Range C: 08 to 0800 psig (055.16 to 05515.8 kPaG).
Range D: 036.26 to 03,626 psig (0250 to 025000kPaG).
Temperature Sensor Ranges
Integral
40°F to 450°F (40°C to 232°C).
Remote
40°F to 850°F (40°C to 454°C).
(1) In most cases, the Mass ProPlate can measure different fluids with different specific
gravity values with no adjustments. High Reynolds number values may cause some
shifts in overall accuracy; consult the factory when high Reynolds numbers
are used.