Emerson Rosemount 2410 - Install Rosemount 2410 Tank Hub in WinSetup

Emerson Rosemount 2410
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 2-3: Typical Configuration of a Rosemount 2410 Connected to PC/Host
A
C H
B
D
E
F
G
A. Field devices
B. Tankbus
C. Rosemount 2410
D. Primary bus: TRL2 Modbus, RS485 Modbus
E. Secondary bus: Enraf and others, HART 4-20 mA analog output/input
F. Modem
G. USB / RS232
H. TankMaster
A THUM Adapter, connected to the Intrinsically Safe Secondary
(3)
bus, allows wireless
communication between a Rosemount 2410 Tank Hub and a Smart Wireless Gateway.
Figure 2-4: Typical Configuration of a Rosemount 2410 with Wireless Connection to
Smart Wireless Gateway and PC/Host
A
D
C
B
E
G
H
F
A. Field devices
B. Tankbus
C. Rosemount 2410
D. Secondary bus (IS): WirelessHART
E. Smart Wireless THUM Adapter
F. Primary bus: TRL2 Modbus, RS485 Modbus
G. Smart Wireless Gateway
H. TankMaster
(3)
The Non-IS Secondary Bus can not be used simultaneously with the IS HART 4-20 mA Secondary Bus.
Overview Reference Manual
December 2019 00809-0100-2410
14 Reference Manual