EasyManua.ls Logo

Emerson Rosemount 3100 Series - The 3102, Level, Content (Volume) or Flow of Liquids

Emerson Rosemount 3100 Series
144 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reference Manual
00809-0100-4840, Rev. BA
July 2008
A-7
Rosemount 3100 Series
The 3102, Level, Content (Volume) or Flow of liquids
Model Product Description
3102 Ultrasonic level transmitter with two integral relays
Code Signal Output
H 4–20 mA with HART
®
communication
Code Housing Material
A Polyurethane-covered Aluminum
Code Conduit / Cable Threads
1 ½–14 NPT
2 M20 x 1.5 adapter
Code Wet-side material
F PVDF
Code Process Connection
RC 2-in. NPT thread
(1)
(1) Choosing this option implies US (Imperial) units of measurement are required for the default configuration. Configuration can be changed on-site.
SC 2-in. BSPT thread
(2)
(2) Choosing this option implies Metric units of measurement are required for the default configuration. Configuration can be changed on-site.
Example model order code: 3102-H-A-1-F-RC-G5-C4-ST
Code Certificates
NA No certification
G5 FM Ordinary Location
G6 CSA Ordinary Location
Code Options
Alarms
C4 Namur alarm and saturation levels; high alarm.
C5 Namur alarm and saturation levels; low alarm.
C8 Low alarm setting with standard Rosemount alarm and saturation levels.
Tag Plate
ST Stainless Steel engraved tag plate
WT Laminated paper tag plate

Table of Contents

Related product manuals