Reference Manual
00809-0100-4840, Rev. BA
July 2008
B-5
Rosemount 3100 Series
ATEX Intrinsically Safe
Approval
I1 Certificate: Sira 06ATEX2260X
Intrinsically Safe for II 1 G, EEx ia IIC
Temperature Class:
T4 (T
amb
-40°C to +60°C)
T6 (T
amb
-40°C to +55°C)
Ui = 30 V, li = 120 mA, Pi = 0.82 W, Li = 108 μH, Ci = 0 μF
Special conditions for safe use:
1. All transmitter models have external plastic parts, which could present a
risk of ignition due to electrostatic charge build-up. They shall not be
directly installed in any process where its enclosure might be charged by
the rapid flow of non-conductive media.
2. All transmitter models shall only be cleaned with a cloth.
3. When the transmitter housing uses aluminium alloy in its construction,
this presents a risk of ignition due to impact and shall be taken into
consideration on installation and use.
Figure B-3.
Approval Labels ATEX
WARNING
RISK OF ELECTROSTATIC CHARGE BUILD UP ON PLASTIC
SURFACES. CLEAN ONLY WITH A DAMP CLOTH
LEVEL TRANSMITTER
3100 SERIES ULTRASONIC
3105xxxxxx
moc.tnuomesor.www
yyyy
3105xxxxxxI1xx
Manufactured by
Mobrey Ltd.
Slough, SL1 4UE, UK
0518
Ui:30V Ii:120mA
Pi:0.82W Ci:0µ
F
Li:108µH
T4(-40°C ≤ Ta ≤ +60°C
T6(-40°C ≤ Ta ≤ +55°C
SIRA 06A TEX2260X
II 1 G EEx ia II C
TYPE 4X / IP66
12...30 Vdc 4-20mA
-30...+70
C -0.25...+3 bar
°
Made in:
Model No.
K9833_3105_ATEX_IS
K9827_3105_NAMEPLATE