Table A-26: Rosemount 5301 and 5302 Level and/or Interface in Liquids Ordering Information
(continued)
Country certification
J1 Canadian Registration Number (CRN)
J2
(23)
ASME B31.1
J7
(24)
Indian Boiler Regulation (For witnessed Form III-C from factory, order certificate Q47 on separate line
Item)
J8
(25)(26)
EN Boiler (European Boiler Approval in accordance with EN 12952-11 and EN 12953-9)
Dye penetration test certificate
Q73 Certificate of Liquid Penetrant Inspection
Positive material identification certificate
Q76 Positive Material Identification Certificate of Conformance
Materials certification
N2
(27)
NACE
material recommendation per NACE MR0175/ISO 15156 and NACE MR0103/ISO 17945
Marine / shipboard approvals
(28)
SBS American Bureau of Shipping Type Approval
SDN Det Norske Veritas Germanischer Lloyd (DNV GL) Type Approval
SLL
(29)
Lloyd's Register Type Approval
SBV Bureau Veritas Type Approval
Installation options
LS
(30)
Long stud 9.8 in (250 mm) for flexible single lead probe to prevent contact with wall/nozzle. Standard
stud length is 3.9 in (100 mm) for probes 5A and 5B.
BR 316L Mounting Bracket for 1½-in. NPT Process Connection (RA) (see Figure A-36)
Weight and anchoring options for flexible single probes (probe type 5A)
W3 Heavy weight (recommended choice for most applications) Weight=2.43 lb (1.10 kg), Length=5.5 in.
(140 mm), Diameter=1.5 in. (37.5 mm)
W2 Short weight (when measuring close to the probe end) Weight=0.88 lb (0.40 kg. Length=2 in. (50
mm), Diameter=1.5 in. (37.5 mm)
Weight assembly options for flexible single probes
WU Weight or chuck not mounted on the probe
Transient protection
T1 Transient Protection Terminal Block. Selectable with HART 4-20 mA output (output code H). Already
included in all FOUNDATION Fieldbus variations.
Diagnostic functionality
D01 FOUNDATION Fieldbus Diagnostics Suite (includes Signal Quality Metrics diagnostics)
DA1 HART Diagnostics Suite (includes Signal Quality Metrics diagnostics)
Specifications and reference data Reference Manual