EasyManua.ls Logo

Emerson ROSEMOUNT 5300 - Application Example 1

Emerson ROSEMOUNT 5300
324 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reference Manual
00809-0100-4530, Rev BA
July 2009
Rosemount 5300 Series
5-42
Application Example 1 Radar Level Transmitter, Level Value
A level transmitter is measuring the level in a 33 ft. (10 m) high tank.
Figure 5-12. Situation Diagram
Solution
Table 5-9 lists the appropriate configuration settings, and Figure 5-13
illustrates the correct function block configuration.
Table 5-9. Analog Input
Function Block Configuration for
a typical Level Transmitter
Figure 5-13. Analog Input
Function Block Diagram for a
typical Level Transmitter
33 ft
(10 m)
100%
0%
Parameter Configured Values
L_TYPE Direct
XD_SCALE Not Used
OUT_SCALE Not Used
CHANNEL CH1: Level
Level Measurement
To Another
Function Block
OUT_D
OUT
AI Function Block