115
Reference Manual
00809-0100-4026, Rev HA
Section 5: Basic Configuration/Start-up
November 2014
Basic Configuration/Start-up
5.10 Application examples
5.10.1 Radar level transmitter - level value
Situation
A level gauge is measuring the level in a 33 ft (10 m) high tank.
Figure 5-17. Situation Diagram
Solution
Table 5-5 lists the appropriate configuration settings, and Figure 5-18 illustrates the correct
function block configuration.
Table 5-5. Analog-Input Function Block Configuration for a Typical Level Gauge
Figure 5-18. Analog-Input Function Block Diagram for a Typical Level Transmitter
Parameter Configured values
L_TYPE Direct
XD_SCALE Not Used
OUT_SCALE Not Used
CHANNEL CH1: Level
33 ft
(10 m)
100 %
0 %
Level measurement
To another
function block
OUT_D
OUT
AI function block