EasyManua.ls Logo

Emerson Rosemount 5400 Series - Configure

Emerson Rosemount 5400 Series
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Quick Start Guide
19
June 2016
5.0 Configure
Basic configuration can easily be done either with Rosemount Radar Master, a
Field Communicator, the AMS
Suite, DeltaV
, DTM, or any other DD (Device
Description) or DTM compatible host system. For advanced configuration
features, Rosemount Radar Master (RRM) is recommended.
5.1 RRM
1. Start RRM.
2. Connect to the desired transmitter.
3. In the Guided Setup window, select Run Wizard for guided setup and follow the
instructions.
4. Select Configure Thresholds and False Echo Areas.
5. Select Restart the Device.
6. Select Verify level.
7. Select Archive Device.
8. Select View live values from device to verify the transmitter works correctly.
5.2 AMS Device Manager or Field Communicator
Step 1: Connect to device
AMS Device Manager
1. Start AMS Device Manager.
2. Select View > Device Connection View.
3. In the Device Connection View, double-click the modem icon.
4. Double-click the device icon.

Other manuals for Emerson Rosemount 5400 Series

Related product manuals