EasyManua.ls Logo

Emerson Rosemount 5402 - Page 267

Emerson Rosemount 5402
338 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product Certifications
255
Product Certifications
October 2018
Reference Manual
00809-0100-4026, Rev KC
Figure B-1. Installation Drawing Ex n Rosemount 5400 Series
ORIGINAL SIZE A3
2015-11-27 08:05
9240031-958_I03_PREL
ISSUE
MODIF. ORDER NO.
WEEK
ISSUE
MODIF. ORDER NO.
WEEK
ISSUE
MODIF. ORDER NO.
WEEK
1
SME-5859
1041
2
SME-6864
1126
3
SME-8392
1538
ISSUED BY
WEEK
DOC. TYPE
PRODUCT CODE
TITLE
EE-VM
1041
6
5400
INSTALLATION DRAWING Exn
ROSEMOUNT 5400 SERIES
APPROVED BY
WEEK
FILE
EAP
1041
Word
The copyright/ownership of this document is
and will remain ours. The document must not
be used without our authorization or brought
to the knowledge of a third party.
Contravention will be prosecuted.
Rosemount Tank Radar AB, Sweden
DOC NO.
ISSUE
PAGE
9240031-958
3
1/1
NON
-HAZARDOUS LOCATION HAZARDOUS LOCATION
HART:
42.4 VDC,
23 mA
FOUNDATION FIELDBUS:
32 VDC, 21
mA
Note 1
nA
Ui: 42.4 V
Ii: 23
mA
Pi:
1 W
Li: Negligible
Uo: 42.4 V Ci: 7.25 nF
ic Io: 23 mA Note 1
Po:
1 W
Lo > 0
Co > 7.25 nF
Notes:
1 Connect supply wires to the appropriate terminals as indicated on the terminal block label
and in the installation documents.
SPECIFIC CONDITIONS FOR SAFE USE (X):
1 The intrinsically safe circuits do not withstand the 500V AC test as specified in
IEC 60079-11 clause 6.4.13.
2 The antennas for type 5400, are non-conducting and the area of the non-conducting parts exceeds the
maximum permissible areas for Group IIC and according to EN/ IEC 60079-0: .2012/2011 clause 7.4:
20 cm
2
/ 80 cm
2
for EPL Gc. Therefore, when the antenna is used in a potentially explosive atmosphere,
appropriate measures must be taken to prevent electrostatic charge.
Input parameter
s for Non-sparking
Model
Parameters
Ambient
Temperature Limits
CURRENT LOOP / HART
42.4 VDC, 23 mA 50 T
a
70 °C
FOUNDATION FIELDBUS
32 VDC, 21 mA 50 T
a
60 °C
Input parameter
s for Energy Limited
Model
Parameters
Ambient
Temperature Limits
CURRENT LOOP
/
HART
U
i
= 42.4 V, I
i
= 23 mA, P
i
= 1.0 W
C
i
= 7.25 nF, L
i
: Negligible
50 T
a
70 °C
FOUNDATION FIELDBUS
U
i
= 32 V, I
i
= 21 mA, P
i
= 0.7 W
C
i
= 4.95 nF, L
i
: Negligible
50 T
a
60 °C
POWER
SUPPLY
EX-CERTIFIED PRODUCT
No
modifications permitted without
reference to the Ex
-
certifying Authorities.
POWER
SUPPLY
Barrier