118
Reference Manual
00809-0200-4702, Rev CA
Appendix B: Product Certifications
February 2013
Product Certifications
Special Conditions for Safe Use (X)
1. The surface resistivity of the antenna is greater than 1G. To avoid electrostatic change
build-up, it must not be rubbed or cleaned with solvents or a dry cloth.
NM ATEX Intrinsic Safety for Mining applications
Certificate No.: Baseefa 07ATEX0239X
Applicable Standards: IEC 60079-0: 2011, EN60079-11: 2012
Markings: I M1 Ex ia I Ma (-60 °C Ta +70 °C)
1180
IP66 / IP67
FOR USE WITH EMERSON PROCESS MANAGEMENT SMART POWER OPTION 701PBKKF
WARNING – POTENTIAL ELECTROSTATIC CHARGING HAZARD – SEE INSTRUCTIONS
Special Conditions for Safe Use (X)
1. The surface resistivity of the antenna is greater than 1G. To avoid electrostatic change
build-up, it must not be rubbed or cleaned with solvents or a dry cloth.
SWITCH TERMINAL OUTPUT
PARAMETER LIMITS Option Code
32
FUEL SENSOR TERMINAL
PARAMETERS Option Code 61
U
o
= 6.6 V U
o
= 7.8 V
I
o
= 13.4 mA I
o
= 92 mA
P
o
= 21.8 mW P
o
= 180 mW
C
i
= 0.216 uF C
i
= 10 nF
Co
IIC
= 23.78 uF Co
IIC
= 9.2 uF
Co
IIB
= 549.78 uF Co
IIB
= 129 uF
Co
IIA
= 1000 uF Co
IIA
= 1000 uF
Li=0 Li=0
Lo
IIC
= 200 mH Lo
IIC
= 4.2 mH
Lo
IIB
= 800 mH Lo
IIB
= 16.8 mH
Lo
IIA
= 1000 mH Lo
IIA
= 33.6 mH
SWITCH TERMINAL OUTPUT PARAMETER LIMITS Option Code 22
U
o
= 6.6 V
I
o
= 26 mA
P
o
= 42.6 mW
C
o
= 11 uF
L
o
= 25 mH
SWITCH TERMINAL OUTPUT
PARAMETER LIMITS Option Code 32
U
o
= 6.6 V
I
o
= 13.4 mA
P
o
= 21.8 mW
C
i
= 0.216 uF
Co
IIC
= 23.78 uF
Co
IIB
= 549.78 uF
Co
IIA
= 1000 uF
Li=0
Lo
IIC
= 200 mH
Lo
IIB
= 800 mH
Lo
IIA
= 1000 mH