Specifications and Reference Data
May 2019
100
Rosemount 8600 Vortex Flow Meter
Figure A-2. Remote Mount Transmitters
Note
Consult factory for SST installation.Dimensions are in
inches (millimeters).
Table A-16. Flanged-Style Flowmeter (8-in./200 mm Line Sizes) (Refer to Figure A-1)
Nominal
Size in.
(mm)
Flange
Rating
Face-to-face A
in. (mm)
Diameter B in.
(mm)
C in. (mm)
Weight
(1)
lb
(kg)
8 (200)
ANSI 150
ANSI 300
9.8 (250)
11.4 (290)
7.55 (191,8)
7.55 (191,8)
13.2 (335)
13.2 (335)
141.6 (64,2)
198.7 (90,1)
PN 16
PN 40
9.8 (250)
12.2 (310)
7.55 (191,8)
7.55 (191,8)
13.2 (335)
13.2 (335)
109.4 (49,6)
156.5 (71,0)
1. Add 0.2 lb (0,1 kg) for display option.
5.77
(147)
1
/2-14 NPT (For Remote Cable
Conduit)
2.00 (51)
3.12
(80)
6.77
(172)
2.44
(62)
3.20
(81)
2.56
(65)
1.10
(28)
2.85
(72)
1.00
(25,4)
4.35
(110)
3.06
(78)
Display
Option
Terminal Cover