Implementing a Universal Transmitter
March 2016
Reference Manual
00809-0300-4750, Rev CA
235
Implementing a Universal Transmitter
D.5.6 Fischer and Porter Sensor to Rosemount 8750W
Transmitter
Connect coil drive and electrode cables as shown in Figure D-10.
Figure D-10. Generic Wiring for Fischer and Porter Sensors and Rosemount 8750W
A. Electrodes
B. Coils
C. Chassis ground
Refer to Figure D-1 on page 225 for actual terminal block configuration drawing.
Fischer and
Porter
Sensors
Rosemount
8750W
Transmitter
Table D-11. Fischer and Porter Generic Sensor Wiring Connections
Rosemount 8750W Fischer and Porter Sensors
1 M1
2 M2
3 Chassis ground
17 3
18 1
19 2
Do not connect mains or line power to the magnetic flowtube sensor or to
the transmitter coil excitation circuit.
1
2
17
18
19
3
A
B
2
1
3
C
M2
M1