Implementing a Universal Transmitter
March 2016
Reference Manual
00809-0300-4750, Rev CA
245
Implementing a Universal Transmitter
D.11 Yamatake Honeywell Sensors
Connect coil drive and electrode cables as shown in Figure D-20.
D.11.1 Yamatake Honeywell Sensor to Rosemount 8750W
Transmitter
Figure D-20. Generic Wiring for Yamatake Honeywell Sensors and Rosemount 8750W
Refer to Figure D-1 on page 225 for actual terminal block configuration drawing.
Yamatake
Honeywell
Sensors
Rosemount
8750W
Transmitter
D. Chassis ground
E. Electrodes
F. Coil s
Table D-21. Yamatake Honeywell Sensor Wiring Connections
Rosemount 8750W Yamatake Honeywell Sensors
1 X
2 Y
3 Chassis ground
17 C
18 B
19 A
Do not connect mains or line power to the magnetic flowtube sensor or to
the transmitter coil excitation circuit.
1
2
17
18
19
3
E
F
A
B
C
D
Y
X