94
Reference Manual
00809-0100-4772, Rev FA
Troubleshooting
March 2016
Troubleshooting
Figure 7-8. Loosening the Housing Rotation Screws
A. Housing rotation screws
B. Support tube
4. Slowly pull the electronics housing no more than 1.5 in. from the top of the
support tube. See Figure 7-9.
Note
When the housing sensor header and sensor cable nut are connected, do not pull the
housing more than 1.5 in. (40 mm) from the top of the support tube. Damage to the sensor
cable may occur if the sensor cable is stressed.
Figure 7-9. Removing Electronics Housing
A. Sensor cable nut—SMA connector
B. Housing sensor header
C. 1.5 in. maximum (40mm) while sensor cable is connected to the sensor header
A
B
A
B
C