12
6
Pressure Transmitter used to Measure Level in an Open
Tank
Situation #2
The transmitter in situation #1 is installed below the tank in a position where the liquid column
in the impulse line, when the tank is empty, is equivalent to 2.0 psi (Figure 7-11).
Figure 7-11 Situation #2 Diagram
Solution
Table 7-24 lists the appropriate configuration settings.
Table 7-24 Analog Input Function Diagram for a Pressure Transmitter used in Level Measurement
(Situation #2
Parameter
Configured Values
L_TYPE
Indirect
XD_SCALE
2 to 9 psi
OUT_SCALE
0 to 16 ft