EasyManua.ls Logo

Emerson unidrive m200 - Page 19

Emerson unidrive m200
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Unidrive M200-201 Quick Start Guide 19
Issue Number: 6
Figure 4-10 Pr 00.005 = Preset (60 Hz)
Figure 4-11 Pr 00.005 = Pad (50 Hz & 60 Hz)
*Refer to Drive User Guide.
1
2
4
0V
Voltage speed reference
input (AI 1)
Reference select
5
+ 10 V output
7
9
10
Digital output
(zero frequency)
Not stop
11
12
13
14
Jog forward
Run
Analog output 1
(motor frequency)
Reference select
+ 24 V output
Terminal 5 Terminal 14 Reference selected
0 0 Preset speed 1*
0 1 Preset speed 2*
1 0 Preset speed 3*
1 1 Preset speed 4*
1
2
4
0V
Voltage speed reference
Voltage speed reference
input (AI 2)
input (AI 1)
5
+ 10 V output
7
9
10
Digital output
(zero frequency)
Drive enable
11
12
13
14
Run reverse
Run forward
Analog output 1
(motor frequency)
Analog input 1/
input 2 select
+ 24 V output
When Pr 00.005 is set to Pad, to run in reverse:
Set Pr 00.017 to On
The keypad reference can now be set to a negative
frequency to run the motor in the reverse direction.
Unidrive M200 201 Quick Start Guide English Iss6.book Page 19 Thursday, September 10, 2015 1:48 PM