90 SI-Ethernet User Guide
Issue: 1
This parameter specifies an IP address for a priority connection.
This parameter specifies an IP address for a priority connection.
This parameter specifies an IP address for a priority connection.
6.1.7 Menu 20 – EtherNet/IP Set-up
The Ethernet interface supports the EtherNet/IP protocol and conforms to the EtherNet/
IP adaptation of the Common Industrial Protocol (CIP) Specification. This is the same
upper-layer protocol and object model as used in DeviceNet.
The Ethernet interface will operate as a slave device and the following functionality is
supported.
Variable length input assembly object (instance 100) with consistency for up to
20 parameters
S.15.021 Priority Connection 2
Minimum
0
(Display: 0.0.0.0)
Maximum
4294967295
(Display: 255.255.255.255)
Default
0
(Display: 0.0.0.0)
Units
Type 32 Bit User Save Update Rate
Module reset, Modbus
interface reset or Modbus
interface enable
Display Format IP Address Decimal Places 0
Coding RW, BU
S.15.022 Priority Connection 3
Minimum
0
(Display: 0.0.0.0)
Maximum
4294967295
(Display: 255.255.255.255)
Default
0
(Display: 0.0.0.0)
Units
Type 32 Bit User Save Update Rate
Module reset, Modbus
interface reset or Modbus
interface enable
Display Format IP Address Decimal Places 0
Coding RW, BU
S.15.023 Priority Connection 4
Minimum
0
(Display: 0.0.0.0)
Maximum
4294967295
(Display: 255.255.255.255)
Default
0
(Display: 0.0.0.0)
Units
Type 32 Bit User Save Update Rate
Module reset, Modbus
interface reset or Modbus
interface enable
Display Format IP Address Decimal Places 0
Coding RW, BU