SI-Ethernet User Guide 57
Issue: 1
Safety
information
Introduction
Mechanical
installation
Electrical
installation
Getting started Parameters
Key features
and Protocols
PC Applications Security Diagnostics
Glossary of
terms
Index
This reports the links status if it has been loaded. A Reset (S.10.002) is required to load
any changes.
Used to select Tx2 as a standard or synchronous cyclic link.
This parameter is used to set the link number (1 to 255) for the Tx2 link.
-10 Attrib RO Attribute is read only
-9 Attrib missing Attribute is missing
-8 Timeout Timeout
-7 In error The specified link is in error state
-6 Link num in use The link number specified is already in use
-5 Not editable The link specified is not editable
-4 Invalid link num An invalid link number was specified
-3 Invalid args Link number / argument zero or invalid
-2 Too many links Maximum number of links has been reached
-1 Out of memory Failed to allocate memory
0 OK Configuration of link successful
1 Not running Ok, not running
2 OK sync Configuration of synchronous link successful
S.10.020 Tx2 Link Profile
Minimum 0 Maximum 1
Default 0 Units
Type 8 Bit User Save Update Rate Read on reset
Display Format None Decimal Places 0
Coding RW, TE
Value Text Description
0
Std Standard link
1
Sync Synchronized link
S.10.021 Tx2 Link Number
Minimum 0 Maximum 255
Default 0 Units
Type 8 Bit User Save Update Rate Read on reset
Display Format None Decimal Places 0
Coding RW, BU
Value Text Description