EasyManua.ls Logo

Emerson Unidrive M700 - Page 73

Emerson Unidrive M700
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SI-Ethernet User Guide 73
Issue: 1
Safety
information
Introduction
Mechanical
installation
Electrical
installation
Getting started Parameters
Key features
and Protocols
PC Applications Security Diagnostics
Glossary of
terms
Index
This parameter reports the link’s status if it has been loaded. A Reset (S.10.002) is
required to load any changes.
Used to select Rx3 as a standard or synchronous cyclic link.
This parameter is used to set the link number (1 to 255) for the Rx3 link.
This parameter sets the destination parameter for the Rx3 link.
This parameter is used to set the number of contiguous parameters for the Rx3 link.
S.10.060 Rx3 Link Profile
Minimum 0 Maximum 1
Default 0 Units
Type 8 Bit User Save Update Rate Read on reset
Display Format None Decimal Places 0
Coding RW, TE
Value Text Description
0
Std Standard link
1
Sync Synchronized link
S.10.061 Rx3 Link Number
Minimum 0 Maximum 255
Default 0 Units
Type 8 Bit User Save Update Rate Read on reset
Display Format None Decimal Places 0
Coding RW, BU
S.10.062 Rx3 Destination Parameter
Minimum
0
(Display: 0.00.000)
Maximum
499999
(Display: 4.99.999)
Default
0
(Display: 0.00.000)
Units
Type 32 Bit User Save Update Rate Read on reset
Display Format Slot Menu Param Decimal Places 0
Coding RW, PT, BU
S.10.063 Rx3 Parameter Count
Minimum 0 Maximum 10
Default 0 Units
Type 8 Bit User Save Update Rate Read on reset
Display Format None Decimal Places 0
Coding RW, BU