DXi.H 691 742 761 861 931 952 1021 1142
kW
72,2 76,4 85,9 87,3 100,3 104,6 107,4 118,9
kW
67,0 75,8 80,1 80,7 96,5 98,0 99,4 104,5
kW
15,7 16,9 18,7 19,9 21,9 23,5 22,9 26,8
0,93 0,99 0,93 0,92 0,96 0,94 0,93 0,88
m
3
/h
15,1 16,0 18,0 18,4 21,0 22,0 22,4 25,1
kPa
31 11 29 21 26 12 22 15
m
3
/h
17600 20900 20900 20900 25700 25700 25700 25700
n
22223333
Pa
390 365 394 394 414 385 414 386
W/W
5,0 4,9 5,0 4,7 4,9 4,8 5,1 4,8
kW
30 33 36 38 45 49 47 56
A
50 51 58 61 76 74 79 93
A
167 33 168 179 185 47 219 203
V/ph/Hz
400/3/50+N+PE
kg/h
88888888
kg/h
88888888
kW
6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0
A
8,7 8,7 8,7 8,7 8,7 8,7 8,7 8,7
ȝ6FP
300/1250 300/1250 300/1250 300/1250 300/1250 300/1250 300/1250 300/1250
mg/l CaCO
3
100/400 100/400 100/400 100/400 100/400 100/400 100/400 100/400
33333333
kW
18,0 24,0 24,0 24,0 27,0 27,0 27,0 27,0
A
26,0 34,6 34,6 34,6 39,0 39,0 39,0 39,0
33333333
kW
24,0 27,0 27,0 27,0 36,0 36,0 36,0 36,0
A
34,6 39,0 39,0 39,0 52,0 52,0 52,0 52,0
kW
37,4 48,9 48,9 48,9 60,8 60,8 60,8 60,8
m
3
/h
6,5 8,5 8,5 8,5 10,6 10,6 10,6 10,6
kPa
34 48 48 48 42 42 42 42
dm
3
7,1 10,45 10,45 10,45 12,6 12,6 12,6 12,6
l/h
390,0 390,0 390,0 390,0 390,0 390,0 390,0 390,0
l/h
500 500 500 500 500 500 500 500
m
5,4 5,4 5,4 5,4 5,4 5,4 5,4 5,4
l/h
600 600 600 600 600 600 600 600
l/h
900 900 900 900 900 900 900 900
m
6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0
67778888
mm
2210 2565 2565 2565 3100 3100 3100 3100
mm
850 850 850 850 850 850 850 850
mm
1980 1980 1980 1980 1980 1980 1980 1980
Kg
627 749 735 739 900 919 904 995
Kg
634 757 743 748 910 929 915 1006
Kg
638 761 747 752 915 934 920 1011
Kg
634 757
743 748 910 929 915 1006
MTEC.DXi.H/DXi.HF.GB-3 Use and Maintenance technical manual DXi.H/DXi.HF English
Emibyte DXi.H/DXi.HF Direct expansion close control
Performances are referred to the following conditions:
$PELHQWWHPSHUDWXUH&5HODWLYHKXPLGLW\:DWHUWHPSHUDWXUH&
(2)
The fans electrical power has to be added to the ambient load.
:DWHUWHPSHUDWXUH&$PELHQWWHPSHUDWXUH&5HODWLYHKXPLGLW\
Cooling capacity (Total)
(1)
ESP 20 Pa
Cooling cpacity (Sensible)
(1)
ESP 20 Pa
Tot. absorbed power
(2)
ESP 20 Pa
SHR
:DWHUÀRZ
Pressure drop
$LUÀRZ
Fan
Max. ESP
EER
Maximum absorbed power
Maximum absorbed current
starting current
Power supply
+XPLGLÀHU
Steam production (nominal)
Steam production (max.)
Max. absorbed power
Max. absorbed current
6SHFL¿FFRQGXFLELOLW\DW&PLQPD[
Total hardness (min/max)
(OHFWULFDOKHDWHUV
Steps
Power
Absorbed current
2YHUVL]HGHOHFWULFDOKHDWHUV
Steps
Power
Absorbed current
+RWZDWHUFRLO
Heating capacity
(3)
:DWHUÀRZ
Pressure drop (coil + 3 way valve)
Coil internal volume
&RQGHQVLQJZDWHUSXPS
1RPLQDOÀRZ
0D[ÀRZSUHYDOHQFH P
0D[GLVFKDUJHKHLJKWÀRZ P
3
h )
&RQGHQVLQJZDWHUSXPSKXPLGLÀHU
1RPLQDOÀRZ
0D[ÀRZSUHYDOHQFH P
0D[GLVFKDUJHKHLJKWÀRZ P
3
h )
'LPHQVLRQVDQGZHLJKW
Frame
Width
Depth
Height
:HLJKW&RQ¿JXUDWLRQ8
:HLJKW&RQ¿JXUDWLRQ9
:HLJKW&RQ¿JXUDWLRQ'
:HLJKW&RQ¿JXUDWLRQ%

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emicon EMIBYTE DXi.H and is the answer not in the manual?

Emicon EMIBYTE DXi.H Specifications

General IconGeneral
BrandEmicon
ModelEMIBYTE DXi.H
CategoryControl Unit
LanguageEnglish